Thursday, July 30, 2026
RecallGazette

U.S. recall intelligence, updated daily

Check recalls for your vehicle

2013 International Durastar, 2012–2013 International Prostar, 2011–2013 International Transtar and 1 other model Recall: Bolts that fasten the air disc brake caliper to the caliper mounting plate…

NHTSA campaign 12V403000 · Service Brakes, Air · filed Aug 14, 2012 · verified Jul 30, 2026

Units reported
956
Manufacturer
NAVISTAR, INC
Risk
Crash / injury
Owner letters
Mailing began Oct 30, 2012

The defect

Navistar is recalling certain model year 2011-2013 International vehicles manufactured from November 2, 2010 through May 25, 2012, equipped with Bendix air disc brakes. Bolts that fasten the air disc brake caliper to the caliper mounting plate may not have been tightended to their specified torque. This may cause the mouting bolts to become loose and possibly allow the air disc brake caliper to separate from the caliper mounting plate, resulting in an unexpected pull condition during braking application or an unexpected increase in stopping distance.

The risk

An unexpected pull condition during braking application or an unexpected increase in stopping distance, increases the risk of a crash, leading to property damage, personal injury, or death.

Check whether your specific vehicle is affected

Recall campaigns often cover only certain VIN ranges. Enter your VIN on the official NHTSA site to confirm whether your vehicle is included and whether the repair is still open.

Check VIN on NHTSA →

The fix — what to do

Navistar will notify owners, and dealers will replace any missing caliper mounting bolts and tighten caliper mounting bolts, free of charge. The safety recall began on October 30, 2012. Owners may contact Navistar at 1-331-332-1590.

Navistar's recall number is 12522. Customers may also contact The National Highway Traffic Safety Administration's Vehicle Safety hotline at 1-888-327-4236 (TTY: 1-800-424-9153), or go to HTTP://WWW.SAFERCAR.GOV.

Affected vehicles

Related recalls

All International Durastar recalls → · All International recalls →

Source: NHTSA recall database, campaign 12V403000 (manufacturer number 12522). Data last verified Jul 30, 2026.