Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Recall Query · Closed

Air Bag Non-Deployment/Engine Stall

Action number
RQ14002
Opened
Jun 16, 2014
Closed
Mar 2, 2015
Outcome
Recall 14V373000

Manufacturer: Chrysler (FCA US, LLC)

This investigation led to a recall

NHTSA links this probe to recall campaign 14V373000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

In March 2011 Chrysler submitted a defect information report for NHTSA Recall No. 11V139 declaring a defect condition that could cause the ignition key to inadvertently move from the RUN to the ACC position on model year (MY) 2010 Dodge Journey, Grand Caravan, and Chrysler Town and Country.The report identified engine stalling as the defect consequence and cited customer complaints and warranty claims, as well as two rear-end collisions, as leading to the recall action.Chrysler determined that a defective WIN module, which is effectively the equivalent of the ignition switch, was the cause of the inadvertent key rotation, and that a new design WIN module would be installed as a remedy.In Spring 2014 ODI conducted outreach to major light vehicle manufacturers regarding ignition key position and its effect on air bag system availability.The outreach was conducted in connection with NHTSA Recall No. 14V047, a recent recall involving inadvertent ignition key rotation and subsequent air bag disablement in certain GM products.During discussions held in April 2014, Chrysler advised ODI that Chrysler air bag systems of this vintage, including the subject vehicles, revert to energy reserve when the ignition key moves to the ACC or OFF position, and that under energy reserve the air bags would only be available for a short period, approximately two tenths of a second (ODI notes this consequence was not identified in the 11V139 recall report).A review of the ODI consumer database…

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.