Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Engineering Analysis · Closed

REAR TRAILING ARM CORROSION FAILURE

Action number
EA08023
Opened
Oct 28, 2008
Closed
Apr 17, 2009
Outcome
Recall 09V123000

Manufacturer: Hyundai Motor America

This investigation led to a recall

NHTSA links this probe to recall campaign 09V123000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

In a letter dated april 14, 2009, hyundai-kia america technical center, inc (hyundai) notified nhtsa that it will conduct a safety recall of approximately 85,000 model year (my) 2001 through 2003 hyundai santa fe vehicles manufactured prior to january 27, 2003, that are registered and operated in the following salt belt states and the district of columbia:connecticut, delaware, illinois, indiana, iowa, maine, maryland, massachusetts, michigan, minnesota, missouri, new hampshire, new jersey, new york, ohio, pennsylvania, rhode island, vermont, west virginia, and wisconsin.hyundai is recalling the vehicles to remedy a condition where internal corrosion of either the right or left rear trailing arms may result in fracture of the affected arm while driving, which could result in loss of vehicle control and a crash.the rear trailing arms will be inspected in the recalled vehicles using a procedure developed by hyundai to measure metal thickness.parts with perforations from corrosion or with metal below the specified thickness will be replaced with redesigned trailing arms.if the minimum metal thickness is met, drainage holes and and rust proofing material will be added to the existing rear trailing arms.although not subject components of this investigation, hyundai noted it would perform a similar procedure for the front subframes of the subject vehicles. Odi's analysis of complaint data revealed that 99% of all consumer complaints related to trailing arm corrosion were from…

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.