Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Preliminary Evaluation · Closed

Haldex Brake Chamber Failures

Action number
PE21018
Opened
Jul 16, 2021
Closed
Oct 10, 2025
Outcome
Closed without recall

Manufacturer: PACCAR Incorporated

What NHTSA is examining

The Office of Defects Investigation (ODI) opened this Preliminary Evaluation (PE21018) based on eleven Vehicle Owner Questionnaires (VOQ). These VOQs included seven wheel-end fires on various Kenworth and Peterbilt trucks.Several of the VOQs were submitted by a maintenance facility stating that the fires were due to power spring fractures within brake chambers manufactured by Haldex Commercial Vehicle Systems (Haldex). According to the reports, the fractured spring punctured the brake chamber diaphragm, resulting in a partial loss of compressed air to the park brakes, causing the brakes to drag and overheat. ODI sent an information request letter to Haldex on August 3, 2021. On October 17, 2021, Haldex submitted a complete response. In this investigation, ODI analyzed thousands of warranty claims as well as fleet reports of brake chamber replacements. ODI gathered information from multiple vehicle manufacturers and reviewed legal testimony alleging defects and laboratory reports that raised concerns about spring failures initiated by corrosion. ODI found that spring failures were often detectable as soon as they occurred. In the subject incidents, after detecting the failures, some operators continued driving to a maintenance facility rather than stopping and waiting for a mobile technician to address the issue, increasing the risk of fire. While over twenty entities purchased the subject component from Haldex, the VOQs that ODI received involved only PACCAR vehicles. Haldex…

Vehicles under investigation

Haldex Air Brake Actuator2015 Kenworth T6802016 Kenworth T6802017 Kenworth T6802018 Kenworth T6802019 Kenworth T6802017 Peterbilt 579

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.