Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Preliminary Evaluation · Closed

Loss of headlights

Action number
PE20004
Opened
Apr 7, 2020
Closed
Oct 30, 2020
Outcome
Recall 20V612000

Manufacturer: Suzuki Motor USA, LLC

This investigation led to a recall

NHTSA links this probe to recall campaign 20V612000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

The Office of Defects Investigation (ODI) opened this Preliminary Evaluation (PE) on April 17th, 2020 to investigate Early Warning Reporting (EWR) reports submitted by Suzuki alleging loss of headlights on model year (MY) 2018 Suzuki GSX 250R motorcycles.On May 29, 2020, ODI learned, through the Suzuki response to an ODI Information Request (IR) letter, that they were aware of two complaints, multiple field reports, thirty-six warranty claims and one goodwill claim describing headlight failures on the subject motorcycles. Within the field reports, ODI discovered there were many failures involving both the low and high beams on the same motorcycle, resulting in a complete loss of vehicle lighting. All reported failures occurred on MY 2018 bikes equipped with headlight assembly part number 35100-20K30. Additionally, Suzuki made ODI aware of a design change effective February 27, 2018 on MY 2019 motorcycles that resulted in a headlight assembly part number change to 35100-20K31. This design change was made to improve serviceability of the headlamp bulb. According to Suzuki, the holding part of the bulb spring had a structure that allowed the bulb spring to become displaced from its proper mounting position when the bulb spring was removed from the holding claw to replace the bulb. Analysis of headlamp failure data showed that no MY 2019 motorcycles, or bikes manufactured with the updated headlight assembly, experienced a headlight failure. The original headlight assembly was…

Vehicles under investigation

2018 Suzuki GSX250R

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.