Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Preliminary Evaluation · Closed

Driveshaft Failure

Action number
PE10002
Opened
Jan 19, 2010
Closed
Mar 25, 2010
Outcome
Recall 10V071000

Manufacturer: Sutphen Corporation

This investigation led to a recall

NHTSA links this probe to recall campaign 10V071000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

This investigation was opened after ODI was notified by a fire rescue authority that they had multiple driveshaft failures on four of their fire trucks. Allegedly, one driveshaft was ejected from the truck as it was being driven on the highway at a high rate of speed. Sutphen conducted an engineering evaluation and then decided to conduct a safety recall.They will: a.modify the cross members on the pre-2007 vehicles; b.conduct driveshaft re-phasing on the post-2007 vehicles; and c.replace the frame cross members.The action taken by Sutphen resolves this investigation. Accordingly, this investigation is closed.

Vehicles under investigation

2011 Sutphen Chassis2004 Sutphen SPH 1002005 Sutphen SPH 1002006 Sutphen SPH 1002007 Sutphen SPH 1002008 Sutphen SPH 1002009 Sutphen SPH 1002010 Sutphen SPH 100

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.