Preliminary Evaluation · Closed

ALTERNATOR CABLE CHAFING

Action number
PE09042
Opened
Sep 1, 2009
Closed
Dec 8, 2009
Outcome
Recall 09V446000

Manufacturer: Motor Coach Industries

This investigation led to a recall

NHTSA links this probe to recall campaign 09V446000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

This investigation was prompted by a review of service bulletins provided bymci to the agency. Motor coach industries (mci) submitted a service bulletin/product improvement campaign (#3016) in their 579.5 monthly submission regarding an alternator cable chafing issue on d series coaches equipped with a caterpillar c13 engine and a 50dn delco alternator. The bulletin reported the cable can chafe against an engine bracket or as a result of movement within the cable clamps.the corrective action is to install a new cable and support brackets.odi believes that there is a high risk for a thermal event resulting from alternator cables chafing within the engine compartment.odi places increased emphasis on preventing potential fires involving motor coaches and other vehicles which carry large numbers of passengers.in november2009, mci filed a safety recall (09v-346) outlining theirremedy program to resolve this issue. Mci will install a new cable with a heavy duty terminal that does not have a spiral loom over the cable passing through the cable clamps.also, the new clamp and mounting bracket were changed to better align the cable as it passes through the cable clamp thus preventing a chafing condition. The action taken by mci resolves this investigation.accordingly, this investigation is closed.

Vehicles under investigation

2005 MCI D40002006 MCI D40002007 MCI D40002008 MCI D40002005 MCI D40052006 MCI D40052007 MCI D40052008 MCI D40052009 MCI D40052005 MCI D45002006 MCI D45002007 MCI D45002008 MCI D45002009 MCI D4500

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.