Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Engineering Analysis · Closed

Air Bag Clockspring Wiring Failure

Action number
EA15007
Opened
Dec 4, 2015
Closed
Jul 6, 2016
Outcome
Recall 16V290000

Manufacturer: Chrysler (FCA US, LLC)

This investigation led to a recall

NHTSA links this probe to recall campaign 16V290000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

On May 10, 2016, Fiat Chrysler America (FCA) submitted a Part 573 Defect Information Report announcing NHTSA recall 16V290 involving 394,258 model year (MY) 2007-2010 Jeep Wrangler vehicles.Under the recall FCA will replace the clockspring and install a steering wheel back cover and steering wheel column shroud.This recall also includes approx. 4,524 MY2007-2010 right hand drive (RHD) Jeep Wrangler vehicles commonly used for rural postal delivery services.In addition 7,180 MY 2011-2016 right hand drive Jeep Wrangler vehicles were also recalled under 16V288, the same remedy repair will be used.Upon review of the 1,942 MY 2007-2010 Jeep Wrangler consumer complaints, 17,195 warranty reports and field returned parts assessment, FCA concluded that a defect exists in the driver side clockspring assembly, a device that both connects (electrically) the driver air bag to the control module and allows rotational movement between the steering wheel and fixed steering column.Clockspring failure may compromise the air bag circuit causing illumination of the air bag warning lamp, and may result in non-deployment of the driver air bag in a frontal crash.FCA identified a contributing factor in that the recalled vehicles may be subjected to off-road dusty environments and/or usage with the vehicle roof top/doors removed thus allowing dust and moisture to enter the clockspring assembly.FCA advised that the MY 2011 and later Wrangler vehicles had an improved steering column cover/shroud that…

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.