Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Engineering Analysis · Closed

Front Subframe Corrosion Failures

Action number
EA10007
Opened
Dec 20, 2010
Closed
Mar 17, 2011
Outcome
Recall 11V030000

Manufacturer: Ford Motor Company

This investigation led to a recall

NHTSA links this probe to recall campaign 11V030000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

In a January 26, 2011 Defect Information Report, Ford Motor Company (Ford) notified the National Highway Traffic Safety Administration (NHTSA) that it will conduct a safety recall to address corrosion related fractures in the front lower control arm rear attaching brackets and body mount attachments at the rear of the front subframe in approximately 425,288 model year (MY) 1999 through 2003 Ford Windstar vehicles manufactured from April 1998 to July 2003 and either sold or currently registered in the following high corrosion (Salt-Belt) states:Connecticut, Delaware, District of Columbia, Illinois, Indiana, Iowa, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Utah, Vermont, West Virginia and Wisconsin (NHTSA Recall No. 11V-030, Ford Recall No. 11S16).According to Ford, separation of a front lower control arm rear attaching bracket may result in a lower control arm separation and separations of both front subframe rear body mounts may result in separation of the steering intermediate shaft.Either condition could result in diminished vehicle directional control, increasing the risk of a crash.Dealers will inspect the lower control arm rear attachment flanges and the rear body mount sections of the subframe on the right (passenger) and left (driver) sides of the vehicle.Owners of vehicles that pass the inspection will be notified when to return for installation of reinforcement…

Source: NHTSA Office of Defects Investigation records, updated daily. An investigation is not a determination that a defect exists; many probes close without a recall.