Friday, August 7, 2026
RecallGazette

Vehicle problems, recalls & safety intelligence

Engineering Analysis · Closed

TURN SIGNAL FAILURES

Action number
EA02037
Opened
Dec 23, 2002
Closed
Sep 5, 2003
Outcome
Recall 03V327000

Manufacturer: General Motors, LLC

This investigation led to a recall

NHTSA links this probe to recall campaign 03V327000.

Read the recall: what is defective and the free fix →

What NHTSA is examining

By letter dated august 27, 2003, gm notified the agency that it is conducting a voluntary safety recall (nhtsa recall no. 03v327) involving certain model year (my) 2000-2001 chevrolet malibu, oldsmobile alero, and pontiac grand am.gm's recall covers 670,740 vehicles manufactured beginning february 1, 2000 through may 1, 2001 (alero and grand am) and february 1, 2000 through may 31, 2001 (malibu).gm reports that turn signal failure is due to solder joint cracking in the hazard switch, and has identified rapid temperature transitions of the hazard switch and the soldering process as the cause of cracking.electrical current to the turn signals flows through the hazard switch and an open circuit in the hazard switch will cause the exterior turn/hazard lamps to become intermittent or inoperative.gm will replace the hazard switch on all involved vehicles.based on gm's safety recall action, this investigation is closed.